GE IC660BBS103
- ated Voltage: 115VAC or 125VDC.
- Input Voltage Range: 93 - 132VAC.
- Output Voltage Range: 105 - 132VDC.
- Load Current per Point: 2.0 amps.
- Isolation: 1500V block - to - block isolation. Between any group and ground or between any two groups, the isolation can withstand 250VAC/VDC continuous, with a transient rating of 2000V peak for 10 sec.
- Input Filter Time: Selectable from 10 to 100ms in 10ms increments.
Tag:
wechatPhone +8613639522374
Phone: +8613639522374
Email: anikaqx@gmail.com
connect:Anika
- Operating Temperature: 0°C – 60°C.
- Storage Temperature: – 40°C – 80°C.
- Power Dissipation: Maximum 16.8W with 8 inputs on; maximum 45.6W with 8 outputs at 2 amps; maximum 8W required control power (block only).
- Dimensions: 8.83” (22.44 cm) x 3.34” (8.48 cm) x 3.91” (9.93 cm) (HxWxD).
- Weight: 4 lbs. (1.8 kg).
- High Compatibility: It supports both NPN and PNP sensor inputs without the need to distinguish between types, and can be flexibly adapted through the common – terminal wiring method.
- Strong Anti – interference Ability: The block has a group – to – group and bus – isolation design, which can effectively resist electromagnetic noise in industrial fields, avoiding signal misjudgment.
- Diagnostic Function: It has self – diagnostic capabilities such as open – wire detection and over – voltage protection. The fault status can be fed back to the main controller through the Genius bus, which is convenient for quick troubleshooting.
- Flexible Expansion: It can be networked with other modules of the same series through the Genius bus, supporting up to 32 nodes, meeting the system expansion requirements.
- Output Pulse Test Capability: It has an output pulse test function, which can be used to test the output circuit.
- Output Default Values: It supports output power – on default values, and the output can be configured to hold the last state or default when there is a problem.
- Sensor Signal Acquisition: It can be connected to proximity switches, photoelectric switches, limit switches, etc., to transmit on – site switch – quantity signals to the PLC controller.
- Equipment Status Monitoring: It can collect the on – off status of buttons, emergency – stop switches, circuit – breaker auxiliary contacts, etc., as the input conditions for PLC logic control.
- Distributed Control: As a slave – station module of the Genius bus, it can be installed in the field far away from the main controller, reducing wiring costs, and is suitable for the signal – centralized acquisition of large – scale production lines.