Technical Specifications
- Processor: Dual-core ARM Cortex-A9 operating at 450 MHz, enabling real-time execution of complex control algorithms with 1,000 boolean operations completed in 0.043 milliseconds.
- Memory:
- RAM: 256 MB DRAM for real-time data processing and program execution.
- Storage: 128 MB NOR flash memory for firmware storage and application data retention.
- Communication Interfaces:
- Ethernet: Two RJ45 ports (10/100 Mbps) supporting IEC 61850-8-1 (Edition 1/2), Modbus TCP, DNP 3.0, and OPC for seamless integration with SCADA systems.
- Serial: Two RS-232 ports (COM3: non-isolated; COM4: opto-isolated) for configuration tools and legacy device integration.
- Redundancy:
- PRP (Parallel Redundancy Protocol): Built-in redundancy for Ethernet communication, ensuring fault-tolerant operation in star or ring bus architectures.
- CPU Redundancy: Supports hot-swap failover with ≤10 milliseconds downtime for critical systems.
- Power Supply:
- Voltage: 110–240 V AC/DC (19.2–30 V DC for DC input) with 210 mA typical/360 mA maximum current consumption.
- Redundant Power Input: Monitoring and automatic switching for uninterrupted operation.
- Environmental Ratings:
- Operating Temperature: -40°C to +70°C (-40°C to +85°C storage).
- Protection Class: IP20 (dust and solid object protection).
- Vibration Resistance: 0.0375 mm amplitude (10–50 Hz) and 0.5 g acceleration (50–150 Hz).
Functional Features
-
Modular Architecture:
- Supports expansion with up to 96 I/O modules via the CEX bus, compatible with ABB’s S800 I/O system for distributed field device integration.
- Slide-and-lock DIN rail mounting simplifies installation and maintenance in industrial settings.
-
Advanced Communication:
- IEC 61850 Compatibility: Enables station-wide interlocking via GOOSE messages and vertical client-server MMS communication to local/remote SCADA systems.
- Multi-Protocol Support: Integrates with third-party devices using Profibus DP, Ethernet/IP, and IEC 60870-5-103.
-
Protection and Control:
- Comprehensive Protection Functions:
- Overcurrent/Undervoltage: Instantaneous and delayed phase/ground overcurrent protection with directional/non-directional settings.
- Frequency Protection: Underfrequency/overfrequency detection with load shedding capabilities for power stability.
- Differential Protection: High-impedance (HIZ) fault detection for transformer and feeder protection.
- Auto-Reclose Functionality: Configurable for multi-breaker setups, including priority circuits to enhance system resilience.
- Comprehensive Protection Functions:
-
Diagnostic Capabilities:
- Real-Time Monitoring: Front-panel LEDs display CPU load, memory usage, and communication status.
- Self-Test Routines: Built-in diagnostics for fault detection, transmitting alerts through the control system’s HMI.
-
Cybersecurity:
- ISA Secure Certified: Ensures protection against unauthorized access and cyber threats.
- Secure Communication: Encrypted GOOSE and MMS messages for data integrity in critical infrastructure.
Application Scenarios
-
Substation Automation:
- Transmission and Distribution: Controls circuit breakers, isolation switches, and busbar systems in high-voltage substations (up to 500 kV).
- Grid Integration: Manages grid synchronization and power flow optimization in renewable energy plants.
-
Industrial Processes:
- Metallurgy: Monitors rolling mills and galvanizing lines for precise strip thickness control in steel production.
- Water Treatment: Automates pump stations, filtration systems, and chemical dosing in municipal wastewater facilities.
-
Renewable Energy:
- Wind Farms: Coordinates turbine pitch control, grid synchronization, and condition monitoring for optimal energy output.
- Solar Power Plants: Manages inverter systems, energy storage, and grid integration to maximize efficiency.
-
Critical Infrastructure:
- Data Centers: Ensures uninterrupted power supply through redundant control of UPS systems and generator synchronization.
- Oil and Gas: Controls wellhead automation, pressure regulation, and safety shutdown systems in upstream/downstream operations.
Operational Advantages
- Reliability: Engineered for high MTBF (Mean Time Between Failures) with redundant power supplies and surge protection against voltage fluctuations.
- Scalability: Seamless integration with ABB’s 800xA distributed control system, enabling centralized monitoring of complex industrial processes.
- Long-Term Support: Under ABB’s Classic Phase lifecycle model, spare parts and technical assistance are available for up to 10 years after production discontinuation.
Documentation and Support
- Technical Resources: Detailed datasheets, installation manuals, and programming guides are accessible via ABB’s official customer portal (myABB), requiring part number verification.
- Authorized Service: Field calibration, firmware updates, and repair services are provided by ABB-certified partners, ensuring compliance with OEM standards.
- Lifecycle Management: Retrofit kits and migration strategies to newer models (e.g., REF615R) are available for system upgrades.
Key Functional Attributes
- Select-Before-Execute Principle: Ensures secure control operations by requiring explicit confirmation before executing commands.
- Distributed Control Architecture: Supports multi-bay applications with pre-configured interlocking modules for common switchgear arrangements.
- Disturbance Recording: Captures fault waveforms and event logs for post-fault analysis, aiding in root-cause identification.
Discover our other products
KEBA 1pc NEW K2-200 DO 242/B Controller Module DHL or FedEX
KEBA 1PC NEW KEBA KE TOP T70-qqu-Aa0-LK SHIP EXPRESS P4374A YL
KEBA KEBA 1762A / 1762A (USED)
KEBA KEBA SR-161 / SR161 (USED)
KEBA Charging Station Electric Vehicle Enelion LA-32-3-S-0-C-50-EGR-0 for 7900 4.8 2011-
KEBA Charging Station Electric Vehicle KEBA KC-P30-EC240422-E00-GE for 3 (E30) 2.7 1985-
KEBA aico.pendant P61 MA1 KEBA KETOP C50 MA1 Used 100% test by DHL or EMS
KEBA KEBA KETOP MOBILE PANEL 66521 T100R-VX (US)
KEBA KEBA HT401-222-4/0/21572
KEBA KEBA H240/24891 / H24024891 (USED)














There are no reviews yet.